          Shielding signal lines

          信號屏蔽電纜.jpg
          • 信號屏蔽電纜.jpg
          Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of a…

          Description:

          Products overview:
          Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of anti-interference, general shield for the knitting of brass or copper (aluminum), shield grounding when use need, to foreign interference signal is the layer into the earth, and to avoid jamming signal into the inner conductor dry all at the same time reduce the wastage of the transmitted signal.Shielding line is fit for ac rated voltage up to and including 450/750 power electrical appliances, instrumentation and telecommunications equipment, etc.
          This product standards: GB5023-85
          Second, the shielding signal type and name:
          RVV - copper PVF insulation, circular connection soft PVC sheathed wire.
          RVVB - copper core PVC insulated, PVC sheathed flat soft wire connection.
          RVV - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, circular connection soft PVC sheathed wire.
          RVP - 105 ℃ -- 105 ℃ polyvinyl chloride insulated copper heat-resisting, shielding soft wire (cable).
          RVVP - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, shielding the soft PVC sheathed wire (cable).
          RVVB - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, flat connection soft PVC sheathed wire.
          Three, shielding signal lines using features:
          Ac rated voltage: 300/500 to and including 450/750v.
          Wire allowed working temperature for a long time:
          - 25 ~ 70 ℃
          - 25 ~ 105 ℃
          The installation of wire temperature: not less than 15 ℃
          Four, shielding line product structure:

          Five, shielding line size reference data (specification) :
          RVV RVVB 300/500V

          The serial numberSome conclusions by nominal cross section
          (mm2)
          Wire core structureWire reference data

          Dc resistance
          Not when 20 ℃
          Greater than Ω/KM

          The number/single
          Diameter (mm)
          Nominal diameter
          (mm)

          The largest diameter
          (mm)

          The weight of the
          (kg-km)
          12 x 0.7542/0.156.67.646.0026.0
          22 x 0.7542/0.154.2 by 6.65.0 by 7.643.4426.0
          32 x 1.032/0.207.17.855.6619.5
          42 x 1.548/0.208.18.873.4313.3
          52 x 2.548/0.209.811.0110.807.89
          63 x 0.7542/0.157.28.062.7626
          73 x 1.032/0.207.58.472.3919.5
          83 x 1.548/0.208.99.6101.5313.3
          93 x 2.577/0.2010.711.5154.357.89
          104 x 0.7542/0.157.88.677.5926
          114 x 1.032/0.208.49.261.2319.5
          124 x 1.548/0.209.911.0130.9413.3
          134 x 2.577/0.2011.612.5192.487.89
          145 x 0.7542/0.158.79.496.4826.0
          155 x 1.032/0.209.111.0112.2919.5
          165 x 1.548/0.2011.012.0164.2513.3
          175 x 2.577/0.2012.914.0239.057.89


          Browse:
          Return To The Top
          Flow Meter Division | Level Instrument Division | Pressure Instrument Division | Thermometer Division | Display Instrument Division | Recording Instrument Division | Calibration Instrument Division
          About
          Honor of qualification
          News
          Technical support The company dynamic Industry news
          Product
          Flow meter series Pressure Instrument Series Thermometer Series Display Instrument Series Recording instrument series Calibration instrument series Proxy instrument series Control valve series Universal valve series Valve fittings series Cable tray series Level instruments
          Contact us
          Tel:0517-86918678 Mobile:15152838848 Email:zhongweick@http://www.gd-haodi.com Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
          [ ??ScanningVisitMobile Version??]
          Copyright ?:Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.??正版建站推廣:韆鞦在線??Su ICP Prepares 11010356-4??

          分亯到:

          ZQvTk