          Cautions for wiring operation of magnetic tilting plate level gauge
          Author:zwck?? Add Time:2019-04-12 11:04:08??

          Magnetically flipped plate level gauge is suitable for liquid measurement in open or pressure vessel. It can measure liquid level safely and reliably under high temperature, high pressure, high viscosity and strong corrosive conditions.

          What are the matters needing attention in wiring operation of magnetic tilting plate level gauge? Before using the magnetic tilting plate level gauge, we should do a good job of wiring the magnetic tilting plate level gauge. If the wiring is wrong, it will lead to inaccurate measurement results. Serious damage will directly cause the instrument. Therefore, we must pay attention to wiring operation.

          Next, let's talk about some requirements and related matters needing attention in connection with magnetic flip plate level gauge.

          In connection with the wiring operation of the magnetic tilting plate level gauge, we should pay attention to the following points:

          1. Large capacity transformers, motors or interference sources should be avoided in wiring.

          2. For explosion-proof type, in order to ensure explosion-proof performance, the wiring must be in accordance with relevant regulations.

          3. Unscrew the terminal cover of the junction box and connect the cable through the cable connector to both ends of the 24VDC.

          4. Connect grounding terminals according to need;

          5. Tighten the terminal cover of the junction box.

          Above is for you to talk about some requirements and precautions about the wiring of magnetic flip-flop level gauge. I hope that through the above description, you will be able to correct wiring operation of magnetic flip-flop level gauge in the future.


          Browse:
          Return To The Top
          Flow Meter Division | Level Instrument Division | Pressure Instrument Division | Thermometer Division | Display Instrument Division | Recording Instrument Division | Calibration Instrument Division
          About
          Honor of qualification
          News
          Technical support The company dynamic Industry news
          Product
          Flow meter series Pressure Instrument Series Thermometer Series Display Instrument Series Recording instrument series Calibration instrument series Proxy instrument series Control valve series Universal valve series Valve fittings series Cable tray series Level instruments
          Contact us
          Tel:0517-86918678 Mobile:15152838848 Email:zhongweick@http://www.gd-haodi.com Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
          [ ??ScanningVisitMobile Version??]
          Copyright ?:Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.??正版建站推廣:韆鞦在(zai)線??Su ICP Prepares 11010356-4??

          分亯到:

          YCYpy